Division

CANWIN Products

CANWIN

Our Proposal

Why Choose CANWIN through HPC Infra

HPC Infra SRL is the only official CANWIN representative in Argentina, with local engineering capabilities and comprehensive supply management.

3D Wound Core Technology

Three-dimensional core that reduces no-load losses by up to 25% compared to conventional cores. Lower operating temperature, longer lifespan, and noise level reduction of up to 10 dB.

IEC-60076 Certification + FAT

Each unit includes auditable Factory Acceptance Tests (FAT): loss measurement, short-circuit impedance, temperature-rise, and dielectric tests. 100% compliance with IEC / IEEE / GB standards.

Flexible Supply Model

HPC manages the complete supply chain: manufacturing, FAT inspection, international logistics, and customs clearance. For clients authorized as importers, we offer a direct import model with CAPEX savings. Lead times: 35 days manufacturing + 55 days transit.

Local Engineering in Argentina

Pre-sales technical consulting, equipment specification for tenders, FAT coordination, and post-sales support. Our team has extensive experience in Oil & Gas, Mining, Data Centers, and Renewable Energy.

Adaptation to Argentine Standards

Equipment configured for Argentine grid voltage levels (13.2 kV / 33 kV) and local site conditions: altitude (derating), ambient temperature, and harmonic K-factor.

CAPEX and OPEX Reduction

The superior efficiency of CANWIN transformers (lower no-load and load losses) generates measurable energy savings throughout the equipment's lifespan, providing a proven return on investment.

Technical Catalog

Product Families

Select a transformer family to view detailed comparative technical specifications.

CANWIN Oil-Immersed Transformer

Oil-Immersed Transformers

Applications: Outdoor Substations, Industrial Plants, Oil & Gas, Wind & Solar Energy, Open-Pit Mining.

Built with high-strength steel tanks and ONAN/ONAF cooling via detachable radiators. The 3D Core series (S13, S22) utilize a spirally wound core that eliminates air gaps, reducing additional losses.

Rango: 30 kVA — 31.500 kVA (31.5 MVA)  |  AT hasta: 35 kV

ONAN / ONAFRele BuchholzValvula PRVOTI / WTIIEC 60076Cu / Al
Tabla 1 — Especificaciones Comparativas: Transformadores en Aceite por Seriess
SeriessCore TechnologyEfficiency Level Power Rating (kVA)HV Voltage (kV)LV Voltage (kV) Vector GroupUk%No-Load LossesNoise (dB)
S11Conventional (Stacked)IEC Standard30 — 31.5006 / 11 / 13.2 / 330.4 / 0.48 / 2.3Dyn11 / Yyn04.0 — 6.5 %Base 100%max. 68
S13 (3D)3D Wound CoreHigh Efficiency30 — 2.50011 / 13.2 / 330.4 / 0.48Dyn11 / Yzn114.0 — 6.0 %approx. 75% of S11max. 58 (−10 dB)
S20 (Amorfa)Amorphous AlloyUltra Efficiency50 — 2.50013.2 / 20 / 330.4Dyn114.0 — 6.0 %approx. 25% of S11max. 55
S22 (Amorfa 3D)Amorphous + 3D CorePremium / Tier 150 — 2.50011 / 13.2 / 330.4Dyn114.0 — 5.5 %approx. 20% of S11max. 52
Tabla 2 — Instrumentacion Standard por Rango de Potencia
Accessory30 — 100 kVA160 — 630 kVA800 — 2.500 kVAMayor 2.500 kVA
Buchholz Relay (Alarm + Trip)StandardStandardStandard
PRV (Pressure Relief Valve) + MicroswitchStandardStandard
OTI (Oil Temperature Indicator)StandardStandardStandard
WTI (Winding Temperature Indicator)StandardStandard
ONAF Forced CoolingOptionalStandardStandard
OCTC (Off-Circuit Tap Changer) +/- 2x2.5%StandardStandardStandardStandard
OLTC (On-Load Tap Changer)OptionalAvailable
Transformador Seco CANWIN

Dry-Type Transformers (Cast Resin / VPI)

Applications: Underground mining, Data Centers, Hospitals, High-rise buildings, Offshore, Food industry.

Vacuum-cast epoxy resin insulation (Cast Resin) free of flammable or polluting fluids. Class F (155°C) or Class H (180°C). Suitable for indoor installation without special vault requirements.

Rango: 30 kVA — 4.000 kVA  |  AT hasta: 35 kV

AN / AFIP00/IP20/IP31Sin aceiteClase F/HPT100Cu / Al Foil
Tabla 3 — Especificaciones Comparativas: Transformadores Secos por Seriess
SeriessAislamientoClase Termica Power Rating (kVA)HV Voltage (kV)Material Bobinado Cooling MethodNoise (dB)Proteccion IP
SC(B)10Resina EpoxiClase F (155°C)30 — 3.1506/11/13.2/35Cu Foil / Al FoilAN / AF (+40%)50 — 65IP00 / IP20 / IP23
SC(B)11Resina EpoxiClase F / H30 — 3.1506/11/13.2/35Cu Foil / Al FoilAN / AF (+40%)48 — 60IP00 / IP20 / IP23
SC(B)13Resina EpoxiClase H (180°C)50 — 4.00013.2/20/35Copper (CU)AN / AF (+50%)45 — 58IP20 / IP31
SC(B)14Epoxi + Nucleo AmorfoClase F / H50 — 2.50011 / 13.2Cu FoilAN / AF45 — 55IP20 / IP31
SG (VPI)Impregnacion VacioClase F30 — 2.5006/11/13.2Cu / AlAN52 — 68IP00 / IP20
Tabla 4 — Equipamiento y Proteccion: Transformadores Tipo Seco
ComponentSC(B)10 / SGSC(B)11SC(B)13 / SC(B)14Funcion
PT100 Temperature SensorStandardStandardStandardActiva alarma y disparo.
PTC Electronic ControllerOptionalStandardStandardDisplay digital + SCADA.
AF Forced CoolingOptionalOptionalAvailable+40% SC10/11, +50% SC13.
IP20 EnclosureOptionalOptionalAvailableZonas peatonales.
IP31 Enclosure (Anti-drip)OptionalAvailableSemisotanos y zonas humedas.
Regulacion OCTC +/-2x2.5%StandardStandardStandardAjuste de tension en vacio.
Padmounted ZGS CANWIN

Pad-Mounted Substations (ZGS / American Box)

Applications: Underground urban developments, Solar and wind parks, Industrial parks, Airports, Shopping centers.

Integrates the distribution transformer, medium-voltage disconnectors (SF6 or Vacuum), and LV distribution panel into a single stainless-steel enclosure. No perimeter fencing required. Radial or Loop feed configurations.

Rango: 75 kVA — 2.500 kVA  |  AT: 11.5 / 13.2 / 33 kV

Sin cerco perimetralRadialLoop / MallaBay-O-NetSF6 / Vacio
Tabla 5 — Especificaciones: Subestaciones Padmounted ZGS
ZGS TypeConfiguracionPower Rating (kVA) HV Voltage (kV)Tension BT (V) HV ProtectionInterruptor MTAislamiento
ZGS-H (Terminal)Radial — Un unico origen75 — 2.50011.5/13.2/33400 / 480Fusible Bay-O-Net + LimitadorSF6 o VacioAceite Mineral/Vegetal
ZGS-Z (Loop)Anillo — Doble origen MT75 — 2.50011.5/13.2/33400 / 480Fusible Bay-O-Net + LimitadorSF6 o VacioAceite Mineral/Vegetal
Tabla 6 — Resumen Comparativo por Familia de Producto CANWIN
CriterionnAceite S11Aceite S13/S22 (3D)Seco SC(B)10/11Seco SC(B)13Padmounted ZGS
Power Range30—31.500 kVA30—2.500 kVA30—3.150 kVA50—4.000 kVA75—2.500 kVA
Max. HV Voltage33 kV33 kV35 kV35 kV33 kV
Cooling MethodONAN/ONAFONAN/ONAFAN/AFAN/AFONAN
Fire RiskLowLowNoneNoneLow
Outdoor InstallationSiSiCon gabinete IPCon gabinete IPSi
Indoor/Basement InstallationSala especialSala especialSin requisito especialSin requisito especialSin cerco
Preventive MaintenanceAceite anualAceite anualMinimo/VisualMinimo/VisualAceite anual
Data Center ApplicationSolo exteriorSolo exteriorInterior directoInterior directo
Manufacturing StandardIEC 60076IEC 60076IEC 60076-11IEC 60076-11IEC 60076/ANSI

Complete Technical PDF Datasheet

Catalog with all IEC specification tables, models, instrumentation, and accessories. Ready to be attached to quotes and tenders.

Download PDF Brochure

Quote Request (RFQ)

Technical Specifications & Contact

Complete the details of your technical requirement. Pressing the button will open your email client with all the information pre-loaded and ready to send.

Technical Requirement Details

Applicant Details

Message us on WhatsApp